Calibration and Dosimetry Laboratory
The Calibration and Dosimetry Laboratory is accredited by the National Accreditation Body (ENAC), Calibration Laboratory No. 23, in accordance with the ISO 17025 standard to perform:
- Calibration of monitors for environmental dosimetry and personal dosimetry, quality control equipment in X-ray and standard ionization cameras in gamma radiation, X-ray and beta radiation qualities.
- Calibrations of portable surface pollution monitors
- Calibration of high voltage size equipment in X-ray equipment
- Irradiation of personal and environmental dosimeters.
You will find our Price list here. If the service requires preparation or any additional service that is not priced, it will be billed separately. Contact us for any questions you may have or to hire our services.
1. Radiation monitors
Quality |
Radionuclide |
Equipment type |
Number of dosage rate points |
Number of dose points |
Prices in € (IVA not included) |
|
S-Cs |
137Cs |
Radiation monitors |
Up to 4 |
0 |
329 |
|
S-Cs |
137Cs |
Radiation monitors |
From 5 to 8 |
0 |
426 |
|
S-Cs |
137Cs |
Radiation monitors |
Up to 8 |
1 |
541 |
|
S-Cs |
137Cs |
Radiation monitors |
Up to 8 |
From 2 to 4 |
625 |
|
S-Cs |
137Cs |
Radiation monitors |
Up to 8 |
From 5 to 7 |
717 |
|
|
|
Direct reading personal dosimeters |
2 |
2 |
329 |
For other points, consult with the laboratory.
The transport of the equipment is not included in the cost of the service provided.
Quality |
Tension |
Dose rate |
Dose |
Price in € (IVA not included) |
|
X-ray (ISO) |
No |
Up to 6 points |
0 points |
541 |
|
X ray (ISO) if the calibration with Cs is also performed |
No |
Up to 6 points |
0 points |
414 |
|
X ray (ISO) |
No |
Up to 3 points |
1 point |
541 |
|
X ray(ISO) |
No |
From 4 to 9 points |
1 point |
625 |
|
X ray (diagnosis or mammography) |
No |
Up to 6 points |
0 points |
541 |
|
X ray (diagnosis or mammography) |
No |
Up to 5 points |
1 point |
541 |
|
X ray(kV) |
Yes |
No |
No |
541 |
|
X ray (kV i diagnosis) 1 sensorª |
Yes |
Up to 5 points |
1 point |
1.081 |
|
X ray(kV and diagnosis) 2 sensorsº |
Yes |
Up to 5 points per sensor |
1 point per sensor |
1.423 |
For other points, consult with the laboratory.
ª RTI ELECTRONICS equipment model BARRACUDA (with an MPD sensor) AND PIRANHA 1579euros.
º RTI ELECTRONICS equipment model BARRACUDA (with an MPD sensor and an additional sensor) and PIRANHA (with an additional sensor): 1922euros.
Equipment
- Ionization chamber, brand Nuclear Entrerprises, model NE2575
- Ionization chamber, Nuclear Entrerprises brand, model NE2530
- Electrometer, brand NE Technology, model Ionex Dosemaster 2590
2. Surface contamination monitors
|
Prices in € (IVA not included) |
Determination of the response of the contamination monitor |
426 |
Determination of the response of the contamination monitor is also carried out the calibration with Cs |
329 |
3. Irradiation of thermoluminescence dosimeters
Quality |
Delivered dose |
Prices in € (IVA not included) |
|
S-Cs |
Up to 2.5mSv (15 min) |
261 |
|
S-Cs |
5 mSv (30min) |
323 |
|
S-Cs |
10 mSv (70 min) |
362 |
|
S-Cs |
From 10 to 50 mSv |
536 |
|
X ray |
Up to 3 mSv |
323 |
|
Beta |
- |
323 |
The indicated prices correspond to radiation with the coronal plane of the dosimeter carrier (normal incidence) perpendicular to the radiation axis incident. For studies of the angular response of dosimeters, consult with the laboratory.
4. Usage of the laboratory
Quality |
Prices in € (IVA not included) |
S-Cs |
295 |
X-ray |
511 |
Share: